Trauma Case Reports (Feb 2017)

Resuscitative endovascular balloon occlusion of the aorta with a low profile, wire free device: A game changer?

  • James N. Bogert,
  • Karole M. Davis,
  • Tammy R. Kopelman,
  • Sydney J. Vail,
  • Paola G. Pieri,
  • Marc R. Matthews

Journal volume & issue
Vol. 7
pp. 11 – 14

Abstract

Read online

A 24 year old male arrived to our hospital after a motor cycle crash with evidence of a traumatic brain injury and in hemorrhagic shock not responsive to volume administration. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) was performed in a timely fashion using a new, low profile, wire free device. This lead to rapid reversal of hypotension while his bleeding source was sought and controlled.Recently, REBOA has emerged as an adjunct in the hypotensive trauma patient with noncompressible torso hemorrhage. As first described, this procedure makes use of commonly available vascular surgery and endovascular products requiring large introducer sheaths (12–14 French) and long guidewires. Concerns regarding this technique center around the safety and feasibility of using such equipment in the emergency setting outside an angiography suite. This has likely limited widespread adoption of this technique. To address these concerns, newer products designed to be placed through a smaller sheath (7 French) and without the use of guidewires have been developed. Here we report on our first clinical use of such a device that we believe represents a significant advance in the care of the trauma patient. Keywords: REBOA, Resuscitation, Hemorrhage, Endovascular