Axial Resolution Enhancement of Optical Sectioning Structured Illumination Microscopy Based on Three-Beam Interference
Chao Xiao,
Xing Li,
Jia Qian,
Wang Ma,
Junwei Min,
Peng Gao,
Dan Dan,
Baoli Yao
Affiliations
Chao Xiao
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
Xing Li
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
Jia Qian
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
Wang Ma
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
Junwei Min
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
Peng Gao
School of Physics, Xidian University, Xi’an 710071, China
Dan Dan
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
Baoli Yao
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
As a branch of 3D microscopy, optical sectioning structured illumination microscopy (OS-SIM) has the advantages of fast imaging speed, weak photobleaching and phototoxicity, and flexible and compatible configuration. Although the method of using the one-dimensional periodic fringe pattern projected on the sample can remove the out-of-focus background from the in-focus signal, the axial resolution of the final reconstructed 3D image is not improved. Here, we propose a three-beam interference OS-SIM, namely TBOS, instead of the common-used dual-beam interference OS-SIM (DBOS). The three-beam interference scheme has been adopted in 3D super-resolution SIM (3D-SR-SIM), where the fringe phase shifting needs to be along each of the three orientations. In contrast, TBOS applies phase shifting only in one arbitrary direction. We built a TBOS SIM microscope and performed the 3D imaging experiments with 46 nm diameter fluorescent microspheres and a mouse kidney section. The axial resolution of the 3D image obtained with TBOS was enhanced by a factor of 1.36 compared to the DBOS method, consistent with the theoretical analysis and simulation. The OS-SIM with enhanced axial resolution for 3D imaging may find a wide range of applications in the biomedical field.