Frontiers in Cardiovascular Medicine (Jul 2022)

Early Results of a Novel Hybrid Prosthesis for Treatment of Acute Aortic Dissection Type A With Distal Anastomosis Line Beyond Aortic Arch Zone Zero

  • Arash Mehdiani,
  • Yukiharu Sugimura,
  • Louise Wollgarten,
  • Moritz Benjamin Immohr,
  • Sebastian Bauer,
  • Hubert Schelzig,
  • Markus Udo Wagenhäuser,
  • Gerald Antoch,
  • Artur Lichtenberg,
  • Payam Akhyari

DOI
https://doi.org/10.3389/fcvm.2022.892516
Journal volume & issue
Vol. 9

Abstract

Read online

IntroductionAcute aortic dissection type A (AADA) is associated with high perioperative morbidity and mortality. A novel non-covered hybrid prosthesis (Ascyrus Medical Dissection Stent (AMDS) Hybrid Prosthesis, Cryolife/Jotec, Hechingen, Germany) can be easily implanted to stabilize the true lumen (TL), improve remodeling, and preserve organ perfusion. Although developed for implantation in aortic zone 0, occasionally, partial replacement of the aortic arch and further distal implantation of AMDS may appear favorable. Implantation of AMDS with anastomosis line beyond zone 0 has not been described yet.Materials and MethodsBetween 08/2019 and 12/2020, a total of n = 97 patients were treated due to AADA at a single University hospital. Of those, n = 28 received an AMDS hybrid prosthesis, of whom in eight patients, due to intraoperative finding the distal anastomosis line was placed distal to the brachiocephalic trunk. Three patients had AMDS implantation in zone I and four were treated by implantation of the prostheses in zone II, and one patient had the implantation performed in zone III. Clinical outcome and the development of a proportional area of TL and false lumen (FL) at defined levels of the thoracic aorta were analyzed.ResultsNone of the surviving patients (87.5%) showed signs of clinical malperfusion (i.e., stroke, spinal cord injury, and need for dialysis). A postoperative CT scan showed an open TL in all patients. The proportion of TL with respect to total aortic diameter (TL+FL) was postoperatively significantly higher in zone III (p = 0.016) and at the level of T11 (p = 0.009). The mean area of TL+FL was comparable between pre- and postoperative CT-scan (p = n.s.). One patient with preoperative resuscitation died of multiple organ failure on extracorporeal life support on postoperative day 3.ConclusionImplantation of AMDS can be safely performed in patients who need partial replacement of the aortic arch beyond zone 0. The advantages of the AMDS can be combined with those of the total arch repair (remodeling of the arch and prevention of TL collapse) without the possible disadvantages (risk of spinal cord injury).

Keywords