Arthroscopy Techniques (Oct 2019)

Arthroscopic and Fluoroscopic Guidance Removal of Intratendinous Broken Instrument During Rotator Cuff Repair

  • Niti Prasataporn, M.D.,
  • Kitiphong Kongrukgreatiyos, M.D.,
  • Vantawat Umprai, M.D.,
  • Thongchai Laohathaimongkol, M.D.,
  • Thun Itthipanichpong, M.D.

Journal volume & issue
Vol. 8, no. 10
pp. e1111 – e1114

Abstract

Read online

Instrument breakage during arthroscopic rotator cuff repair is a rare complication of shoulder arthroscopy, especially when the broken instrument has been left inside the tendon part of the rotator cuff. We propose a combined arthroscopy and fluoroscopic guidance technique to ease the removal of the broken instrument and repair the torn rotator cuff after removal.