Scientific Reports (Jul 2023)
Research on the air supply adjustment technology of breath-following powered air-purifying respirators
Abstract
Abstract In the hope of reducing the air supply flow of the powered air-purifying respirator (PAPR) and extending the service life of the filter, a breath-following powered air-purifying respirator (BF-PAPR) that can dynamically adjust the air supply flow according to the breathing flow is proposed. The BF-PAPR changes the air supply flow by adjusting the speed of the variable-frequency centrifugal fan according to the air velocity at the half mask outlet (v hm ) monitored by the modular wind speed transmitter. In the study, the air supply flow adjustment model of the BF-PAPR is developed. It is found that the filtration resistance barely influences v hm . In addition, under the same mean inhalation flow, the minimum outlet air velocity increases first and then decreases with the increase of the duty cycle variation coefficient (λ), while the maximum outlet air velocity decreases first and then increases. Moreover, the minimum air supply flow of the BF-PAPR is achieved when the standard value of the air velocity is 13.4 m/s and the value of λ is 1. The BF-PAPR can reduce the air supply flow by 6.5%-8.6% and the energy consumption by approximately 20% compared with the PAPR, which is beneficial for reducing the usage cost and extending the continuous working time.