The Egyptian Heart Journal (Feb 2024)

Differing radiation exposure in scrub technicians and rotating staff in Cardiac catheterization laboratory: occupation matters

  • Muhammad Nasir Rahman,
  • Maleeha Javed,
  • Ghufran Adnan,
  • Maria Khan,
  • Zeenat Nizar,
  • Izat Shah

DOI
https://doi.org/10.1186/s43044-024-00448-8
Journal volume & issue
Vol. 76, no. 1
pp. 1 – 5

Abstract

Read online

Abstract Background Radiation exposure is a significant hazard associated with invasive Cardiology, with most studies based on primary operator exposure. This prospective, observational study aimed to find out over lead radiation exposure as effective dose acquired by non-physician staff comprising scrub technicians and rotating staff in the cath laboratory. Effective dose (ED) measured per procedure via Raysafe i2®dosimeter badges worn by both rotating staff and scrub technicians over lead aprons along with dose area product (DAP), fluoroscopy time (FT) and procedure time (PT) in minutes was collected prospectively over forty-six invasive Cardiology procedures. Results This study shows that rotating staff acquire higher ED in comparison with their scrub technician colleagues in diagnostic, interventional and electrophysiology cases. However, a statistically significant difference in radiation exposure of both staff groups was demonstrated in diagnostic and interventional Cardiology procedures, with p values of 0.04 and 0.01, respectively. Conclusions These findings highlight occupational role and mobility around fluoroscopic sources as major factors in radiation exposure, which should be addressed within current radiation protection practices.

Keywords