Applied Sciences (Feb 2023)

Revamping Fluid Catalytic Cracking Unit, and Optimizing Catalyst to Process Heavier Feeds

  • Dicho Stratiev,
  • Mihail Ivanov,
  • Ivan Chavdarov,
  • Georgi Argirov,
  • Giulia Strovegli

DOI
https://doi.org/10.3390/app13032017
Journal volume & issue
Vol. 13, no. 3
p. 2017

Abstract

Read online

H-Oil gas oils have a higher density and higher nitrogen content, and consequently much lower reactivity than straight-run vacuum gas oils during fluid catalytic cracking (FCC). The conversion of H-Oil gas oils observed in a laboratory catalytic cracking unit at constant operating conditions showed a 20 wt.% lower conversion rate than straight-run hydrotreated vacuum gas oil. Thus, a revamp of commercial FCC units, and the selection of a higher activity catalyst with lower coke selectivity is needed to provide the stable trouble-free operation of the unit. The performed revamp of the commercial FCC unit allowed a stable operation at a higher throughput. It also allowed an increased riser outlet temperature from 532 to 550 °C; increased maximum allowable regenerator temperature from 705 to 730 °C; decreased afterburning from 12 to 6 °C; decreased NOx emissions in the flue gas from 250 to 160 mg/Nm3; improved catalyst regeneration; decreased catalyst losses to 0.0142 kg/t feed; and improved catalyst circulation at a higher throughput. It was confirmed in the commercial FCC unit that the H-Oil light vacuum gas oil is the least reactive H-Oil gas oil during catalytic cracking.

Keywords