Acta Chimica Slovenica (Jun 2017)

Electroanalytical Determination of Escitalopram Oxalate Using Nickel Nanoparticles Modified Carbon Paste Sensor

  • Ali Kamal Attia,
  • Mona A Mohamed,
  • Amany M Fekry

DOI
https://doi.org/10.17344/acsi.2017.3193
Journal volume & issue
Vol. 64, no. 2
pp. 415 – 421

Abstract

Read online

A sensitive voltammetric method was described for the determination of escitalopram oxalate based on electrocatalytic oxidation at nickel nanoparticles modified chloranil carbon paste sensor in Britton-Robinson buffer (pH range from 2 to 10). The modified electrode was characterized by scanning electron microscopy, electrochemical impedance and cyclic voltammetry. The investigation of electrochemical behavior of escitalopram oxalate was performed using cyclic voltammetry and differential pulse voltammetry. The anodic peak current showed a linear range from 1.0 x 10-6 to 7.0 x 10-5 mol L-1. The detection limit is below 2.0 x 10-7 mol L-1. The proposed method is rapid, economical, simple, precise and sensitive voltammetric method for the determination of escitalopram oxalate in bulk, dosage form and urine.

Keywords