BMC Infectious Diseases (Jan 2020)
Comparative study of Revogene GBS LB assay and GeneXpert GBS LB assay for the detection of group B Streptococcus in prenatal screening samples
Abstract
Abstract Background Group B Streptococcal (GBS) infections in the United States are a leading cause of meningitis and sepsis in newborns. The CDC therefore recommends GBS screening for all pregnant women at 35–37 weeks of gestation and administration of intrapartum prophylaxis (in those that tested positive) as an effective means of controlling disease transmission. Several FDA approved molecular diagnostic tests are available for rapid and accurate detection of GBS in antepartum women. Method In this study, we report a clinical comparison of the Xpert GBS LB assay and a novel FDA-cleared test, Revogene GBS LB assay. A total of 250 vaginal-rectal swabs from women undergoing prenatal screening were submitted to the University of Wisconsin’s clinical microbiology laboratory for GBS testing. Results We found 96.8% of samples were concordant between the two tests, while 3.2% were discordant with a positive percent agreement of 98.0% and a negative percent agreement of 96.5% between the Revogene GBS LB assay and the GeneXpert GBS LB assay. Conclusion Overall, we report that both assays perform well for the detection of GBS colonization in pregnant women.
Keywords