PLoS ONE (Jan 2023)

Advancing proficiency testing for ultra in resource-limited settings using dried tube specimen: A study by SRL-Uganda.

  • Joel Kabugo,
  • Joanita Namutebi,
  • Isa Adam,
  • Dennis Mujuni,
  • Didas Tugumisirize,
  • Oola Denis,
  • George William Kasule,
  • Ivan Ibanda,
  • Beatrice Orena,
  • Henry Byabajungu,
  • Elizabeth Nampewo,
  • Moses Joloba

DOI
https://doi.org/10.1371/journal.pone.0282650
Journal volume & issue
Vol. 18, no. 3
p. e0282650

Abstract

Read online

BackgroundProficiency testing (PT) has been hard to set up due to cost limitations and technical capacity. Conventional Xpert MTB/RIF PT programs use liquid and culture spots which require stringent storage and transportation conditions with cross-contamination chances prevalent. These setbacks prompted the use of dried tube specimens (DTS) for Ultra assay PT. For continuity of PT provision, stability of DTS and compatibility with testing protocols when kept for a long period needs to be established.MethodsDTS were prepared from known isolates inactivated using a hot air oven at 85°C. 100μl of bacterial suspensions were aliquoted and dried inside a Biosafety cabinet. Panel validation was done to establish the baseline Deoxyribonucleic acid (DNA) concentration in terms of cycle threshold (Ct) value. DTS aliquots were shipped to participants to test and report within six weeks. The remaining DTS were kept at 2-8°C and room temperature for one year with testing at six months. Twenty (20) DTS samples per set remaining at one year were heated at 55°C for two weeks before testing. The means of the different samples were compared to validation data using paired t-tests. Boxplots were designed to visualize the differences in the medians of the DTS.ResultsOverall mean Ct value increased by 4.4 from the validation to testing after one year at the different storage conditions. Samples heated at 55°C showed a 6.4 Ct difference from validation data. Testing done at six months on 2-8°C stored items showed no statistical difference. At all the remaining testing times and conditions, P-values were less than 0.008 although the absolute mean Ct when compared showed slight increments and accommodated differences for the detection of MTB and rifampicin resistance. Median values for samples stored at 2-8°C were lower compared to those at room temperature.ConclusionDTS stored at 2-8°C remain more stable for one year compared to higher temperatures and can be consistently used as PT materials in more than one PT round for biannual PT providers.