Energies (Nov 2023)
Impact of Uninsulated Slab-on-Grade and Masonry Walls on Residential Building Overheating
Abstract
Studies of the effects of removing underfloor insulation and increasing the thermal capacity of building walls are currently found almost exclusively in existing vernacular architecture and rammed-earth buildings, mostly in countries with warm climates. This paper proposes the combined use of these two measures to reduce the risk of overheating in a detached single-family house in a temperate climate during the summer. Experimental studies conducted during the largest heat wave on record in the summer of 2019 showed that peak daytime temperatures decreased by 5.2 °C to 7.1 °C, and peak nighttime temperatures decreased by 4.7 °C to 6.8 °C. Simulation studies taking into account occupant heat showed that the proposed passive methods could, under the IPCC 8.5 scenario, eliminate the need for mechanical cooling in a detached single-family house in the temperate climate of Central and Eastern Europe by 2100. The actual heating energy consumption for the building with an uninsulated floor and increased wall heat capacity was 5.5 kWh/m2 higher than for the reference building, indicating that it can be a near-zero energy building. The proposed concept is in line with the new approach to the energy design of buildings, which should not be limited to reducing thermal energy demand, but should also respond to the needs arising from global warming.
Keywords