Abstract

Read online

Abstract A significant prosthetic paravalvular leak is an uncommon and severe postsurgical complication correlated to the occurrence of congestive heart failure and hemolytic anemia. Percutaneous treatment has become an attractive and effective proposal to relieve symptoms and reduce complications in patients whose high rate of morbidity/mortality precludes a new surgery. This is the case of an 81-year-old patient with a history of biological aortic valve replacement seeking medical help due to heart failure and hemolytic anemia, with a prosthetic paravalvular regurgitation jet and high surgical mortality according to EuroSCORE II.