PLoS ONE (Jan 2016)

Automated Protein Localization of Blood Brain Barrier Vasculature in Brightfield IHC Images.

  • Rajath E Soans,
  • Diane C Lim,
  • Brendan T Keenan,
  • Allan I Pack,
  • James A Shackleford

DOI
https://doi.org/10.1371/journal.pone.0148411
Journal volume & issue
Vol. 11, no. 2
p. e0148411

Abstract

Read online

In this paper, we present an objective method for localization of proteins in blood brain barrier (BBB) vasculature using standard immunohistochemistry (IHC) techniques and bright-field microscopy. Images from the hippocampal region at the BBB are acquired using bright-field microscopy and subjected to our segmentation pipeline which is designed to automatically identify and segment microvessels containing the protein glucose transporter 1 (GLUT1). Gabor filtering and k-means clustering are employed to isolate potential vascular structures within cryosectioned slabs of the hippocampus, which are subsequently subjected to feature extraction followed by classification via decision forest. The false positive rate (FPR) of microvessel classification is characterized using synthetic and non-synthetic IHC image data for image entropies ranging between 3 and 8 bits. The average FPR for synthetic and non-synthetic IHC image data was found to be 5.48% and 5.04%, respectively.