Defence Technology (Mar 2014)

Research on design and firing performance of Si-based detonator

  • Rui-zhen Xie,
  • Xiao-ming Ren,
  • Lan Liu,
  • Yan Xue,
  • Dong-xiao Fu,
  • Rui Zhang

DOI
https://doi.org/10.1016/j.dt.2014.01.002
Journal volume & issue
Vol. 10, no. 1
pp. 34 – 39

Abstract

Read online

For the chip integration of MEMS (micro-electromechanical system) safety and arming device, a miniature detonator needs to be developed to reduce the weight and volume of explosive train. A Si-based micro-detonator is designed and fabricated, which meets the requirement of MEMS safety and arming device. The firing sensitivity of micro-detonator is tested according to GJB/z377A-94 sensitivity test methods: Langlie. The function time of micro-detonator is measured using wire probe and photoelectric transducer. The result shows the average firing voltage is 6.4 V when the discharge capacitance of firing electro-circuit is 33 μF. And the average function time is 5.48 μs. The firing energy actually utilized by Si-based micro-detonator is explored.