Brazilian Journal of Radiation Sciences (Nov 2016)
Modelo quantitativo de avaliação da contribuição de cada fonte radioativa na dose individual externa Hx em trabalhador de serviço de medicina nuclear
Abstract
Assess whether the activities performed in the Nuclear Medicine service are significant in the total dose received by the workers and their relative contributions. Methods: measured independent variables: number of scintigraphies remaining in the examination room (N); eluted activity (E); Total activity marked in pharmaceuticals kits (K); number of times that was scheduled to work in the Hot room (Q); Variable dependent measured: cumulative effective dose in the period 10/2012 to 04/2013 added to each worker, obtained by information registered daily and monthly on activities and doses received in the period. Held Multiple Linear Regression (D = a + β_1 N + E + β_2 β_3 K + β_4 Q) with α = 0.05 significance level. It was concluded that the independent variables N (p = 0.097) and E (p = 0.086) did not significantly interfere with the Cumulative dose in the period. The K variables (p = 0.017) and Q (p = 0.028) were significant in the proposed model.
Keywords