EPJ Web of Conferences (Jan 2019)

Determination of the uncertainty of mass flow measurement using the orifice for different values of the Reynolds number

  • Golijanek-Jędrzejczyk Anna,
  • Mrowiec Andrzej,
  • Hanus Robert,
  • Zych Marcin,
  • Świsulski Dariusz

DOI
https://doi.org/10.1051/epjconf/201921302022
Journal volume & issue
Vol. 213
p. 02022

Abstract

Read online

Standard orifice flowmeters are widely used in the chemical and energy industry. Therefore, it is essential to know how accurate the measurements made with these instruments are. The paper presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. The authors will present the influence of ranges of the Reynolds number on the estimated uncertainty, obtained on the basis of simulation and laboratory experiments. The research was conducted for the central orifice in the Reynolds number 8,000 < Re < 21,000. The results of estimating the extended uncertainty of the measurement of water flow using simulation and experimental method, are convergent. The maximum difference in the extended uncertainty values of flow measurement for the simulation and experiment was 0.04.10-3 kg/s.