BMC Pulmonary Medicine (Jul 2024)

Ultrasound quantification of pleural effusion volume in supine position: comparison of three model formulae

  • Dachuan Tang,
  • Huiming Yi,
  • Wei Zhang

DOI
https://doi.org/10.1186/s12890-024-03142-2
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background To investigate the accuracy of three model formulae for ultrasound quantification of pleural effusion (PE) volume in patients in supine position. Methods A prospective study including 100 patients with thoracentesis and drainage of PE was conducted. Three model formulae (single section model, two section model and multi-section model) were used to calculate the PE volume. The correlation and consistency analyses between calculated volumes derived from three models and actual PE volume were performed. Results PE volumes calculated by three models all showed significant linear correlations with actual PE volume in supine position (all p < 0.001). The reliability of multi-section model in predicting PE volume was significantly higher than that of single section model and slightly higher than that of two section model. When compared with actual drainage volume, the intra-class correlation coefficients (ICCs) of single section model, two section model and multi-section model were 0.72, 0.97 and 0.99, respectively. Significant consistency between calculated PE volumes by using two section model and multi-section model existed for full PE volume range (ICC 0.98). Conclusion Based on the convenience and accuracy of ultrasound quantification of PE volume, two section model is recommended for pleural effusion assessment in routine clinic, though different model formulae can be selected according to clinical needs.

Keywords