Applied Sciences (Apr 2019)

A High-Resolution Ultrasonic Ranging System Using Laser Sensing and a Cross-Correlation Method

  • Lecheng Jia,
  • Bin Xue,
  • Shili Chen,
  • Hanzhong Wu,
  • Xiaoxia Yang,
  • Jingsheng Zhai,
  • Zhoumo Zeng

DOI
https://doi.org/10.3390/app9071483
Journal volume & issue
Vol. 9, no. 7
p. 1483

Abstract

Read online

Ultrasound has been proven to be a valid tool for ranging, especially in water. In this paper, we design a high-resolution ultrasonic ranging system that uses a thin laser beam as an ultrasonic sensor. The laser sensing provides a noncontact method for ultrasound detection based on acousto-optic diffraction. Unlike conventional methods, the ultrasound transmitted from the transducer is recorded as the reference signal when it first passes through the laser. It can be used to improve the accuracy and resolution of the time-of-flight (TOF) by a cross-correlation method. Transducers with a central frequency of 1 MHz and diameters of 20 mm and 28 mm are used in the experiment. Five targets and a test piece are used to evaluate the ranging performance. The sound velocity is measured by the sound velocity profiler (SVP). The repeatability error of TOF is less than 4 ns, and the theoretical resolution of TOF is 0.4 ns. The results show a measurement resolution within one-tenth of the wavelength of ultrasound and an accuracy better than 0.3 mm for targets at a distance up to 0.8 m. The proposed system has potential applications in underwater ranging and thickness detection.