Nuclear Engineering and Technology (Jul 2023)

Thermal-hydraulic analysis of He–Xe gas mixture in 2×2 rod bundle wrapped with helical wires

  • Chenglong Wang,
  • Siyuan Chen,
  • Wenxi Tian,
  • G.H. Su,
  • Suizheng Qiu

Journal volume & issue
Vol. 55, no. 7
pp. 2534 – 2546

Abstract

Read online

Gas-cooled space reactor, which adopts He–Xe gas mixture as working fluid, is a better choice for megawatt power generation. In this paper, thermal-hydraulic characteristics of He–Xe gas mixture in 2 × 2 rod bundle wrapped with helical wires is numerically investigated. The velocity, pressure and temperature distribution of the coolant are obtained and analyzed. The results show that the existence of helical wires forms the vortexes and changes the velocity and temperature distribution. Hot spots are found at the contact corners between helical wires and fuel rods. The highest temperature of the hot spots reach 1600K, while the mainstream temperature is less than 400K. The helical wire structure increases the friction pressure drop by 20%–50%. The effect extent varies with the pitch and the number of helical wires. The helical wire structure leads to the reduction of Nusselt number. Comparing thermal-hydraulic performance ratios (THPR) of different structures, the THPR values are all less than 1. It means that gas-cooled space reactor adopting helical wires could not strengthen the core heat removal performance. This work provides the thermal-hydraulic design basis for He–Xe gas cooled space nuclear reactor.

Keywords