Absolute and Relative Reliability of the Assessment of the Muscle Mechanical Properties of Pelvic Floor Muscles in Women with and without Urinary Incontinence
Daiana Priscila Rodrigues-de-Souza,
Sandra Alcaraz-Clariana,
Lourdes García-Luque,
Cristina Carmona-Pérez,
Juan Luis Garrido-Castro,
Inés Cruz-Medel,
Paula R. Camargo,
Francisco Alburquerque-Sendín
Affiliations
Daiana Priscila Rodrigues-de-Souza
Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain
Sandra Alcaraz-Clariana
Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain
Lourdes García-Luque
Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain
Cristina Carmona-Pérez
Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain
Juan Luis Garrido-Castro
Department of Computer Science and Numerical Analysis, Rabanales Campus, University of Córdoba, 14071 Córdoba, Spain
Inés Cruz-Medel
Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain
Paula R. Camargo
Laboratory of Analysis and Intervention of the Shoulder Complex, Department of Physical Therapy, Universidade Federal de São Carlos, Rodovia Washington Luis km 235, São Carlos 13565-905, SP, Brazil
Francisco Alburquerque-Sendín
Department of Nursing, Pharmacology and Physical Therapy, Faculty of Medicine and Nursing, University of Córdoba, 14004 Córdoba, Spain
An analysis of the muscle mechanical properties (MMPs) of the pelvic floor muscles (PFMs) is relevant for understanding the physiopathology of urinary incontinence (UI). However, there is no objective and reliable methodology currently available for quantifying the MMPs of PFMs. Thus, the objective was to determine the intra-rater and inter-rater reliability of the MMPs of PFM assessment with a hand-held tonometer device, called the MyotonPRO, in young women with and without UI. Sociodemographic and pelvic floor questionnaires, plus MMPs of PFMs were assessed in 38 nulliparous women with UI and 40 matched healthy women by two trained physiotherapists on two different occasions, 48–72 h apart. Good to excellent absolute reliability was found for tone, stiffness, and decrement of both intra- and inter-rater analyses in both study groups (Intraclass Correlation Coefficient ranged from 0.75 to 0.92), with a trend of lower values for relaxation and creep. The standard error of measurement (SEM) did not achieve 10% of the mean values for any MMPs. The minimum detectable change (MDC) values were also provided for clinical applications. In conclusion, the relative reliability of tone, stiffness, and the assessment of the decrement of PFMs with MyotonPRO is good to excellent for UI and healthy women. The SEM and MDC values were acceptable for their application in clinical settings.