Biology of Sport (Jul 2020)

Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes

  • Brett Nickerson,
  • Noel Medrano,
  • Gabriel Perez,
  • Samantha Narvaez,
  • Joshua Carrillo,
  • Misael Duque

DOI
https://doi.org/10.5114/biolsport.2020.96851
Journal volume & issue
Vol. 37, no. 4
pp. 383 – 387

Abstract

Read online

The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-eight male NCAA Division II athletes (n = 60) participated in the present study. Jump height (JH) values for double-leg CMJs were analyzed by each device using a one-way repeated measures ANOVA whereas a 2 (jump leg) x 3 (wear location) repeated measures ANOVA was employed to evaluate single-leg CMJs. Reliability of the VERT devices were based upon intraclass correlation coefficients (ICC). Double-leg CMJs revealed an excellent ICC between all three VERT devices (ICC = 0.969). However, JH for RH and LH (45.69 ± 9.84 and 45.82 ± 10.45 cm, respectively) were on average lower than W (50.44 ± 12.37cm; both p LH for left-leg CMJs; all p < 0.001). Results suggest that LH and RH are interchangeable for double-leg CMJs, but not with waist despite excellent reliability. In addition, all wear locations provided excellent ICCs for single-leg CMJs. However, waist provides more consistent JH values for right- and left-leg CMJs while RH and LH show more variability.