Abstract

Read online

The efficiency of integrated cooling air at the intake of Turbocharger and Scavenge air at the inlet of working cylinders of the main diesel engine of dry-cargo ship by transforming the waste heat into a cold by an Refrigerant Ejector Chiller (ECh) as the most simple in design and reliable in operation and by complex in design but more efficient Absorption Lithium-Bromide Chiller (ACh) was analyzed. A ship power plant of cogeneration type using the relatively low-grade heat of water of a heat supply system with a temperature of about 90 °C, that significantly complicates the problem of its conversion into cold were considered. Because of the insufficiently high efficiency of transformation of the heat of hot water (low coefficient of performance) as compared with steam, the resulting cooling capacity may not be enough for cooling intake air of the turbocharger and scavenge air, that raises the problem of the rational distribution of heat loads between the Turbocharger Intake Air cooling circuit (subsystem) and Scavenge air cooling circuit and the need to use chillers of various types. This takes into account the rational parameters of cooling processes of the scavenge air in the cogeneration high-temperature stage of scavenge air cooler, in the intermediate stage of traditional cooling air with seawater, and in the low-temperature stage for deep cooling of the scavenge air by using a chiller. A new approach is proposed to improve the efficiency of integrated cooling Intake Air of the turbocharger and Scavenge Air at the inlet of the working cylinders of the ship main engine of a transport ship, which consists in comparing the required cooling capacity and the corresponding heat needs during the trade route with the available heat of exhaust gases and scavenge air of the cogeneration power plant, determining the deficit and excess cooling capacity of heat utilizing cooling machines of various types, that allows to identify and realize the reserves of improving the efficiency of cooling intake air of the turbocharger and the scavenge air of the main diesel engine through the joint use of chillers of various types.

Keywords