Revista Brasileira de Terapia Intensiva (Dec 2009)

Comparação entre as variações respiratórias da amplitude de onda pletismográfica da oximetria de pulso e do pulso arterial em pacientes com e sem uso de norepinefrina Comparison between respiratory pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure variations among patients with and without norepinephrine use

  • Guilherme Loures de Araújo Penna,
  • Paula Araujo Rosa,
  • Pedro Martins Pereira Kurtz,
  • Fabricio Braga,
  • Gustavo Ferreira Almeida,
  • Marcia Freitas,
  • Luis Eduardo Drumond,
  • Ronaldo Vegni e Souza,
  • Michel Schatkin Cukier,
  • André Salgado,
  • Clóvis Faria,
  • José Kezen,
  • André Miguel Japiassú,
  • Marcelo Kalichsztein,
  • Gustavo Nobre

DOI
https://doi.org/10.1590/S0103-507X2009000400003
Journal volume & issue
Vol. 21, no. 4
pp. 349 – 352

Abstract

Read online

OBJETIVOS: A variação respiratória da pressão arterial é um bom preditor da resposta a fluidos em pacientes ventilados. Foi recentemente demonstrado que a variação respiratória na pressão arterial de pulso se correlaciona com a variação da amplitude da onda pletismográfica da oximetria de pulso. Nossa intenção foi avaliar a correlação entre a variação respiratória da pressão arterial de pulso e a variação respiratória na amplitude da onda pletismográfica da oximetria de pulso, e determinar se esta correlação foi influenciada pela administração de norepinefrina. MÉTODOS: Estudo prospectivo de sessenta pacientes com ritmo sinusal normal sob ventilação mecânica, profundamente sedados e hemodinamicamente estáveis. Foram monitorados o índice de oxigenação e pressão arterial invasiva. A variação respiratória da pressão do pulso e a variação respiratória da amplitude da onda pletismográfica na oximetria de pulso foram registradas simultaneamente batimento a batimento, e foram comparadas utilizando o coeficiente de concordância de Pearson e regressão linear. RESULTADOS: Trinta pacientes (50%) necessitaram de norepinefrina. Ocorreu uma correlação significante (K=0,66; pOBJECTIVES: Arterial pulse pressure respiratory variation is a good predictor of fluid response in ventilated patients. Recently, it was shown that respiratory variation in arterial pulse pressure correlates with variation in pulse oximetry plethysmographic waveform amplitude. We wanted to evaluate the correlation between respiratory variation in arterial pulse pressure and respiratory variation in pulse oximetry plethysmographic waveform amplitude, and to determine whether this correlation was influenced by norepinephrine administration. METHODS: Prospective study of sixty patients with normal sinus rhythm on mechanical ventilation, profoundly sedated and with stable hemodynamics. Oxygenation index and invasive arterial pressure were monitored. Respiratory variation in arterial pulse pressure and respiratory variation in pulse oximetry plethysmographic waveform amplitude were recorded simultaneously in a beat-to-beat evaluation, and were compared using the Pearson coefficient of agreement and linear regression. RESULTS: Thirty patients (50%) required norepinephrine. There was a significant correlation (K = 0.66; p < 0.001) between respiratory variation in arterial pulse pressure and respiratory variation in pulse oximetry plethysmographic waveform amplitude. Area under the ROC curve was 0.88 (range, 0.79 - 0.97), with a best cutoff value of 14% to predict a respiratory variation in arterial pulse pressure of 13. The use of norepinephrine did not influence the correlation (K = 0.63, p = 0.001, respectively). CONCLUSIONS: Respiratory variation in arterial pulse pressure above 13% can be accurately predicted by a respiratory variation in pulse oximetry plethysmographic waveform amplitude of 14%. The use of norepinephrine does not alter this relationship.

Keywords