Critical Care Explorations (Apr 2023)

The Effectiveness of the Interventions to Reduce Sound Levels in the ICU: A Systematic Review

  • Jeanette Vreman, MSc,
  • Joris Lemson, MD, PhD,
  • Cris Lanting, PhD,
  • Johannes van der Hoeven, MD, PhD,
  • Mark van den Boogaard, RN, PhD

DOI
https://doi.org/10.1097/CCE.0000000000000885
Journal volume & issue
Vol. 5, no. 4
p. e0885

Abstract

Read online

OBJECTIVES:. Excessive noise is ubiquitous in the ICU, and there is growing evidence of the negative impact on work performance of caregivers. This study aims to determine the effectiveness of interventions to reduce noise in the ICU. DATA SOURCES:. Databases of PubMed, EMBASE, PsychINFO, CINAHL, and Web of Science were systematically searched from inception to September 14, 2022. STUDY SELECTION:. Two independent reviewers assessed titles and abstracts against study eligibility criteria. Noise mitigating ICU studies were included when having at least one quantitative acoustic outcome measure expressed in A-weighted sound pressure level with an experimental, quasi-experimental, or observational design. Discrepancies were resolved by consensus, and a third independent reviewer adjudicated as necessary. DATA EXTRACTION:. After title, abstract, and full-text selection, two reviewers independently assessed the quality of each study using the Cochrane’s Risk Of Bias In Nonrandomized Studies of Interventions tool. Data were synthesized according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, and interventions were summarized. DATA SYNTHESIS:. After screening 12,652 articles, 25 articles were included, comprising either a mixed group of healthcare professionals (n = 17) or only nurses (n = 8) from adult or PICU settings. Overall, the methodological quality of the studies was low. Noise reduction interventions were categorized into education (n = 4), warning devices (n = 3), multicomponent programs (n = 15), and architectural redesign (n = 3). Education, a noise warning device, and an architectural redesign significantly decreased the sound pressure levels. CONCLUSIONS:. Staff education and visual alert systems seem promising interventions to reduce noise with a short-term effect. The evidence of the studied multicomponent intervention studies, which may lead to the best results, is still low. Therefore, high-quality studies with a low risk of bias and a long-term follow-up are warranted. Embedding noise shielding within the ICU-redesign is supportive to reduce sound pressure levels.