Journal of Orthopaedic Surgery (Jul 2017)

The use of fluoroscopic guided percutaneous pedicle screws in the upper thoracic spine (T1–T6): Is it safe?

  • Mun Keong Kwan,
  • Chee Kidd Chiu,
  • Chris Yin Wei Chan,
  • Reza Zamani,
  • Nils Hansen-Algenstaedt

DOI
https://doi.org/10.1177/2309499017722438
Journal volume & issue
Vol. 25

Abstract

Read online

Purpose: This study analysed the accuracy and safety of the fluoroscopic guided percutaneous screws in the upper thoracic vertebrae (T1–T6). Methods: Computed tomography scans from 74 patients were retrospectively evaluated between January 2008 and December 2012. Pedicle perforations were classified by two types of grading systems. For medial, lateral, superior and inferior perforations: grade 0 – no violation; grade 1 – 4 mm. For anterior perforations: grade 0 – no violation; grade 1 – 6 mm. Results: There were 35 (47.3%) male and 39 (52.7%) female patients with a total 260 thoracic pedicle screws (T1–T6) analysed. There were 32 screw perforations which account to a perforation rate of 12.3% (11.2% grade 1, 0.7% grade 2 and 0.4% grade 3). None led to pedicle screw-related complications. The perforation rate was highest at T1 (33.3%, all grade 1 perforations), followed by T6 (14.5%) and T4 (14.0%). Conclusion: Fluoroscopic guided percutaneous pedicle screws of the upper thoracic spine (T1–T6) are technically more demanding and carry potential risks of serious complications. Extra precautions need to be taken when fluoroscopic guided percutaneous pedicle screws are placed at T1 and T2 levels, due to high medial pedicular angulation and obstruction of lateral fluoroscopic images by the shoulder girdle and at T4–T6 levels, due to smaller pedicular width.