Blinded rechecking of sputum smear microscopy performance in public health facilities in Tigray region, Northern Ethiopia: Retrospective cross sectional study.

  • Letebrhan Weldemhret,
  • Ataklti Hailu,
  • Goyitom Gebremedhn,
  • Hadish Bekuretsion,
  • Gebreselassie Alemseged,
  • Gebremicheal Gebreegziabher,
  • Gebrhiwot Tesfahuney,
  • Tesfaye Berhe,
  • Lemlem Legesse,
  • Kelali Kalayu,
  • Mesfin Tesfay,
  • Kibrti Mehari

DOI
https://doi.org/10.1371/journal.pone.0239342
Journal volume & issue
Vol. 15, no. 10
p. e0239342

Abstract

Read online

IntroductionTuberculosis disease is the leading cause of death worldwide along with HIV/AIDS. Sputum smear microscopy plays an essential role for initial TB diagnosis and treatment follow up. But, misdiagnosis of sputum smear microscopy revealed a high economical crisis and missing of active TB cases. This study was aimed to determine blinded rechecking of sputum smear microscopy performance in public health facilities in Tigray region, Northern Ethiopia.Materials and methodsA cross sectional retrospective study was conducted from January, 2017 to December, 2018 year. Data was collected retrospectively using electronic and paper based in Tigray health research institute. The data was analyzed using the SPSS version 25 software. The sensitivity, specificity, positive predictive value, and negative predictive value of the smear readings were calculated using 2X2 contingency table. The reading agreement between the microscopic center and reference center was determined using kappa statistics.ResultsA total of 23,456 blinded rechecked smear results were reviewed. In average, the performances of sputum smear quality were 61%, 68%, 64%, 66%, 62% and 75% for specimen quality, staining quality, smear size, smear thickness, smear evenness and smear cleanliness respectively. Of the total error (0.48%) reported, 0.25%, 0.19% and 0.085% were false positive, false negative and quantification errors respectively. The concordance rate of health facilities for smear reading was increased to 90% by the end of 2018. Overall, the sensitivity, specificity, PPV, and NPV of the smear readings were 95%, 99.7%, 93% and 99.8% respectively. Likewise, the smear reading agreement was also perfect with kappa value, 0.87.ConclusionThe overall performance of public health facilities for blinded rechecking of smear microscopy was satisfactory. But, the high false positive and false negative errors found calls for continuous evaluation and monitoring of the health facilities by reference center.