Abstract

Read online

Abstract Background This case highlights several complications of a late and rare presentation of culture-negative Streptococcus pyogenes endocarditis of a previously repaired mitral valve with an annuloplasty ring including recurrent cardioembolic strokes, which was initially missed on transthoracic echocardiography. Case presentation A 66-year-old Caucasian female with prior mitral valve prolapse status post mitral valve annuloplasty and left atrial appendage occlusion, followed by two strokes, presented with supraventricular tachycardia that resolved spontaneously. During an inpatient admission, she developed symptoms of another stroke, and imaging studies were suggestive of recurrent cardioembolic phenomenon. Additional workup revealed two small intra-atrial masses adherent to the mitral annuloplasty ring missed on prior evaluation for recurrent stroke. She underwent surgical repair in the setting of a chronic culture-negative infectious endocarditis with Streptococcus pyogenes and recovered well with no further cardioembolic phenomenon. Conclusion This case serves to highlight the importance of having a higher index of suspicion in any cardiac prosthesis patient for endocarditis when presenting with symptoms such as recurrent stroke, arrhythmias, and abnormal cardiac lab work. It also demonstrates the need for appropriate imaging with transthoracic echocardiography followed by transesophageal echocardiography and reviews surgical indications to diagnose and treat culture-negative endocarditis.

Keywords