Synthesis of Bamboo-like Multiwall Carbon Nanotube–Poly(Acrylic Acid-co-Itaconic Acid)/NaOH Composite Hydrogel and its Potential Application for Electrochemical Detection of Cadmium(II)
Luis F. Chazaro-Ruiz,
Miguel Olvera-Sosa,
Gabriela Vidal,
J. Rene Rangel-Mendez,
Gabriela Palestino,
Fatima Perez,
Wei Zhang
Affiliations
Luis F. Chazaro-Ruiz
División de Ciencias Ambientales, Instituto Potosino de Investigación Científica y Tecnológica, A.C. (IPICYT), Camino a la Presa San José 2055, Lomas 4ª Sección, San Luis Potosí C.P. 78216, SLP, Mexico
Miguel Olvera-Sosa
Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, Manuel Nava No. 6, San Luis Potosí C.P. 78210, Mexico
Gabriela Vidal
División de Ciencias Ambientales, Instituto Potosino de Investigación Científica y Tecnológica, A.C. (IPICYT), Camino a la Presa San José 2055, Lomas 4ª Sección, San Luis Potosí C.P. 78216, SLP, Mexico
J. Rene Rangel-Mendez
División de Ciencias Ambientales, Instituto Potosino de Investigación Científica y Tecnológica, A.C. (IPICYT), Camino a la Presa San José 2055, Lomas 4ª Sección, San Luis Potosí C.P. 78216, SLP, Mexico
Gabriela Palestino
Facultad de Ciencias Químicas, Universidad Autónoma de San Luis Potosí, Manuel Nava No. 6, San Luis Potosí C.P. 78210, Mexico
Fatima Perez
CONACYT—Instituto Potosino de Investigación Científica y Tecnológica, A.C. (IPICYT), Camino a la Presa San José 2055, Lomas 4ª Sección, San Luis Potosí C.P. 78216, SLP, Mexico
Wei Zhang
College of Engineering, Bay Campus, Swansea University, Swansea SA1 8EN, UK
A poly(acrylic acid-co-itaconic acid) (PAA-co-IA)/NaOH hydrogel containing bamboo-type multiwall carbon nanotubes (B-MWCNTs) doped with nitrogen (PAA-co-IA/NaOH/B-MWCNTs) was synthesized and characterized by SEM, absorption of water, point of zero charges, infrared spectroscopy, thermogravimetric analysis, and differential scanning calorimetry. The possible use of the PAA-co-IA/NaOH/B-MWCNT hydrogel as an electrode modifier and pre-concentrator agent for Cd(II) sensing purposes was then evaluated using carbon paste electrodes via differential pulse voltammetry. The presence of the B-MWCNTs in the hydrogel matrix decreased its degree of swelling, stabilized the structure of the swollen gel, and favored the detection of 3 ppb Cd(II), which is comparable to the World Health Organization’s allowable maximum value in drinking water. A calibration curve was obtained in the concentration range of 2.67 × 10−8 to 6.23 × 10−7 M (i.e., 3 and 70 ppb) to determine a limit of detection (LOD) of 19.24 μgL−1 and a sensitivity of 0.15 μC ppb−1. Also, the Zn(II), Hg(II), Pb(II) and Cu(II) ions interfered moderately on the determination of Cd(II).