Frontiers in Rehabilitation Sciences (Feb 2024)

The effect of liquid consistency on penetration-aspiration: a Bayesian analysis of two large datasets

  • James C. Borders,
  • Catriona M. Steele,
  • Catriona M. Steele,
  • Catriona M. Steele

DOI
https://doi.org/10.3389/fresc.2024.1337971
Journal volume & issue
Vol. 5

Abstract

Read online

IntroductionThickened liquids are commonly recommended to reduce the risk of penetration-aspiration. However, questions persist regarding the impact of bolus consistency on swallowing safety. The common practice of summarizing Penetration-Aspiration Scale (PAS) scores based on worst scores is a bias in prior analyses. The aim of this study was to examine the impact of liquid consistency on PAS scores using a Bayesian multilevel ordinal regression model approach, considering all scores across repeated bolus trials. A second aim was to determine whether PAS scores differed across thickener type within consistency.MethodsWe analyzed two prior datasets (D1; D2). D1 involved 678 adults with suspected dysphagia (289 female; mean age 69 years, range 20-100). D2 involved 177 adults (94 female; mean age 54 years, range 21-85), of whom 106 were nominally healthy and 71 had suspected dysphagia. All participants underwent videofluoroscopy involving ≥3 boluses of 20% w/v thin liquid barium and of xanthan-gum thickened barium in mildly, moderately and extremely thick consistencies. D2 participants also swallowed trials of slightly thick liquid barium, and starch-thickened stimuli for each thickened consistency. Duplicate blinded rating yielded PAS scores per bolus, with discrepancies resolved by consensus. PAS ratings for a total of 8,185 and 3,407 boluses were available from D1 and D2, respectively. Bayesian models examined PAS patterns across consistencies. We defined meaningful differences as non-overlapping 95% credible intervals (CIs).ResultsAcross D1 and D2, penetration occurred on 10.87% of trials compared to sensate (0.68%) and silent aspiration (1.54%), with higher rates of penetration (13.47%) and aspiration (3.07%) on thin liquids. For D1, the probability of a PAS score > 2 was higher for thin liquids with weighted PAS scores of 1.57 (CI: 1.48, 1.66) versus mildly (1.26; CI: 1.2, 1.33), moderately (1.1; CI: 1.07, 1.13), and extremely thick liquids (1.04; CI: 1.02, 1.08). D2 results were similar. Weighted PAS scores did not meaningfully differ between thin and slightly thick liquids, or between starch and xanthan gum thickened liquids.DiscussionThese results confirm that the probability of penetration-aspiration is greatest on thin liquids compared to thick liquids, with significant reductions in PAS severity emerging with mildly thick liquids.

Keywords