Applied Sciences (Jun 2024)

Forensic Analysis on Damage of a Cable-Stayed Bridge without Backstays Using BIM Information

  • Qi Xu,
  • Xuefei Shi,
  • Ziqi Xu,
  • Haiying Ma

DOI
https://doi.org/10.3390/app14135538
Journal volume & issue
Vol. 14, no. 13
p. 5538

Abstract

Read online

Serious cracks were found in the pylon of a cable-stayed bridge without backstays. Based on forensic damage investigation, this paper uses the finite element (FE) method incorporating Building Information Modeling (BIM) to analyze the causes of cracking. The BIM model is established based on the survey of design, construction, and service information of the bridge. Then, FE analysis is conducted using BIM information. Finally, the causes of cracking in different regions of the pylon are explained in detail. The results show that the FE simulation agrees well with the inspected distribution of cracks, and the causes of cracks are closely related to the pylon construction process. The main cause of the cracks is the shrinkage difference between concrete segments of different ages. The anchorage effect of stayed cables also causes inclined cracks perpendicular to the cable direction. The combination of temperature load and concrete shrinkage results in cracks at the root of the pylon, and the reduction in cable forces exacerbates the cracking.

Keywords