Abstract

Read online

A new fibre-sampling dual-readout calorimeter prototype has been qualified on beam at two facilities (DESY and CERN) using electrons from 1 to 100 GeV. The prototype was designed to almost fully contain electromagnetic showers and a central module (highly granular readout) was equipped with 320 Silicon Photomultipliers (SiPMs) spaced by 2 mm and individually read out. The test beams performed in 2021, allowed to qualify the readout boards used to operate the SiPMs, to define the calibration procedure and to measure the light yield for scintillating and Cherenkov signals produced by the shower development. This paper reports the first results obtained with the highly granular readout and discusses the ongoing R&D to address some open questions concerning the mechanical integration and the scalable readout scheme that will allow to build and operate the next prototype designed for hadronic showers containment.