An Experimental and Simulation Study on the Formability of Commercial Pure Titanium Foil
Abstract
In order to understand the formability of as-received tempered commercial pure titanium grade 2 foils (CP Ti Gr2) with a thickness of 38 µm, a series of micro limited dome height (µ-LDH) tests were conducted in quasi-static speed (0.01 mm/s) at room temperature without the use of a lubricant. A technique developed at NIU was also used to create micro-circular grids (ϕ50 μm) on the as-received material. The forming limit curve (FLC) of the CP Ti Gr2 foils was obtained through the proposed µ-LDH test. For having mechanical properties of the CP Ti Gr2 foils for LS-Dyna FEA (Finite Element Analysis) simulations, a series of tensile tests in three directions were also conducted at room temperature with the same speed. The obtained FLC has been validated using a micro deep drawing case study in which both FEA simulations and experiments were conducted and compared. It has been proven in this study that the FLC obtained using the proposed µ-LDH test can be used for an extremely thin sheet-metal-forming process by the automotive, aerospace, medical, energy, and electronic industries, etc., right away for product design, forming process development, tool and die designs, and simulations, etc.
Keywords