AIP Advances (Jun 2024)

Two-dimensional sound pressure distribution: Visualization and calibration-free quantification via optical wave microphone CT scanning

  • Than Nu Nu San,
  • Aung Myint Myat,
  • Si Thu Han,
  • Fumiaki Mitsugi

DOI
https://doi.org/10.1063/5.0207291
Journal volume & issue
Vol. 14, no. 6
pp. 065319 – 065319-7

Abstract

Read online

In recent years, the optical wave microphone has emerged as an innovative technique, employing Fraunhofer diffraction of a laser beam, and shows promising applications in various acoustic domains where high electric and/or magnetic fields preclude the use of traditional microphones. This study utilized an optical wave microphone computed tomography (CT) scan and calibration-free quantification to ascertain sound pressure levels at multiple distances from the ultrasonic oscillator. The cornerstone of this study, which is different from the author’s previous studies, is the quantification of sound pressure distribution via a theoretical model that encompasses all physical parameters pertinent to the optical wave microphone’s experimental arrangement. This method has proven effective in visualizing and quantifying the two-dimensional sound pressure distribution emitted by an ultrasonic oscillator (40 kHz) without the necessity for calibration. The results demonstrate that the sound pressure distribution determined using the calibration-free optical wave microphone CT scan is in good agreement with the measurements obtained through a condenser microphone.