PLoS ONE (Jan 2020)

The sound sensation of a pure tone in cochlear implant recipients with single-sided deafness.

  • Jeremy Marozeau,
  • Dan Gnansia,
  • Marine Ardoint,
  • Christine Poncet-Wallet,
  • Diane S Lazard

DOI
https://doi.org/10.1371/journal.pone.0235504
Journal volume & issue
Vol. 15, no. 7
p. e0235504

Abstract

Read online

Ten cochlear implant (CI) users with single-sided deafness were asked to vary the parameters of an acoustic sound played to their contralateral ear to characterize the perception evoked by a pure tone played through the direct audio input of their CI. Two frequencies, centered on an apical and a medial electrode, were tested. In six subjects, the electrode positions were estimated on CT scans. The study was divided in 3 experiments in which the parameters of the acoustic sound varied. The listeners had to vary the frequency of a pure tone (Exp.1), the center frequency and the bandwidth of a filter applied to a harmonic complex sound (Exp.2), and the frequency of the components and the inharmonicity factor of a complex sound (Exp.3). Two testing sessions were performed at 3 and 12 months after activation. The mean results of Exp. 1 showed that the frequency of the matched tone was significantly lower for the apical than for the medial stimulus. In Exp.2, the mean center frequencies of the filters were also significantly lower for the apical than for the medial stimulus. As this parameter modifies the energy ratio between the high and low-frequency components, this result suggests that the medial stimulus was perceived with a brighter timbre than the apical stimulus. In Exp.3, the mean frequencies of the components were not significantly different between the sounds resulting from the stimulation of the two electrodes, but were significantly lower at the12-month session compared to the 3-month visit. These results suggest that a change in place of excitation may be perceived as a change in timbre rather than a change in pitch, and that an effect of adaptation can be observed.