Testing of Regulating and Non-Regulating Hydraulic Pumps

  • Kosiba Ján,
  • Čurgaliová Gabriela,
  • Tkáč Zdenko,
  • Jablonický Juraj,
  • Hanushchak-Yefimenko Liudmyla,
  • Bukoros Tetiana

DOI
https://doi.org/10.2478/ata-2023-0031
Journal volume & issue
Vol. 26, no. 4
pp. 231 – 237

Abstract

Read online

This article deals with the testing of regulating and non-regulating hydraulic pumps in laboratory conditions. The laboratory test was carried out on the hydraulic device consisting of two separate hydraulic circuits (for testing the non-regulating hydraulic pump and regulating hydraulic pump). A throttle valve or proportional throttle valve is used for loading. During the laboratory tests, the flow efficiency of the non-regulating hydraulic pump at rotation speed n = 1,500 rpm (nominal speed) was ηpp = 98.91% (0 MPa) and ηpp = 94.97% (20 MPa), and for the regulating hydraulic pump, the values were ηpp = 97.57% (0 MPa) and ηpp = 94.54% (20 MPa). The determined values of flow efficiency of hydraulic pumps determine the correct operation of the experimental hydraulic laboratory equipment.