Diagnostics (Feb 2021)

Evaluation of the Fetal Left Ventricular Myocardial Performance Index (MPI) by Using an Automated Measurement of Doppler Signals in Normal Pregnancies

  • Su-Min Kim,
  • Soo-Young Ye

DOI
https://doi.org/10.3390/diagnostics11020358
Journal volume & issue
Vol. 11, no. 2
p. 358

Abstract

Read online

The myocardial performance index is widely used as an indicator of the heart’s performance. However, due to the subjective nature of ultrasonic testing, there are differences in the measurements among inspectors, requiring a quantitative and objective assessment. In this study, an automated program was developed to quantitatively evaluate the myocardial performance index (MPI) and the cardiac time intervals in the left ventricle for each trimester. One hundred and thirty-three pregnant women who visited the hospital for prenatal examinations were studied, and skilled inspectors obtained left ventricular blood flow waveforms from 47 fetuses in the 12 weeks, 54 fetuses in the 22 weeks, and 32 fetuses in the 31 weeks of pregnancy using a pulse Doppler mode of ultrasound equipment. The acquired images automatically measured the isovolumetric contraction time (IVCT), isovolumetric relaxation time (IVRT,) ejection time (ET), and filling time (FT), and calculated the Tei index (TI) and the K-index (KI); each interval was manually measured during the actual inspection for comparison. In this study, the ultrasonic Doppler waveform was objectively analyzed and measured by the automated program, and it will help with the evaluation of fetal heart function.

Keywords