Atmospheric Measurement Techniques (Aug 2024)

Evaluation of the effects of different lightning protection rods on the data quality of C-band weather radars

  • C. Hald,
  • M. Schaper,
  • A. Böhm,
  • M. Frech,
  • J. Petersen,
  • B. Lange,
  • B. Rohrdantz

DOI
https://doi.org/10.5194/amt-17-4695-2024
Journal volume & issue
Vol. 17
pp. 4695 – 4707

Abstract

Read online

Lightning protection is important for weather radars to prevent critical damage or outages, but this can have negative effects on data quality. The existing lightning protection of the German Meteorological Service (Deutscher Wetterdienst, DWD) polarimetric C-band weather radar network consists of four vertical poles with a maximum diameter of 10 cm. During radar operation, these rods cause local scattering in the near field of the antenna, resulting in negative impacts on radar products. One effect is the removal of significant transmission power from the main beam axis and its addition to other areas or the side lobes. This results in wrongly localised precipitation fields in a radial direction. The second effect is the loss of transmitted and received power, appearing as a decrease in system gain, and subsequently an underestimation of all power-based radar moments in the vicinity of the rods. The underestimation in radar reflectivity Z then leads to a negative bias of approximately 20 % in the actual rain rate if a Z–R relationship is applied. These detrimental effects on data quality led to the requirement of developing a new lightning protection concept. The new concept must minimise the effect on data quality but also provide sufficient protection from lightning strikes according to the existing regulations and requirements. Three possible lighting protection concepts are described in this paper: two using vertical rods of different diameters (16 and 40 mm) and one with horizontally placed rods outside the antenna aperture. Their possible influence on data quality is quantified through a dedicated measurement campaign by analysing resulting antenna patterns and precipitation sum products. Antenna patterns are analysed with respect to the side-lobe levels compared to antenna patterns without lightning protection and the original lightning protection. With the newly tested lightning rods, the apparent side-lobe levels are slightly increased compared to an antenna pattern taken without lightning protection but are within the accepted antenna specifications. Compared to the original lightning protection, a decrease of up to −15 dB in apparent side-lobe levels is found for all tested lightning protection options. Beam blockage is substantially reduced compared to the existing lightning protection, as shown by the evaluation of quantitative precipitation estimation (QPE) sums. These results and some structural considerations are a solid basis to recommend the installation of four rods with a maximum 40 mm diameter for all 17 radar systems of the DWD weather radar network.