Buildings (Apr 2024)
Comprehensive Analysis of Ferrocement-Strengthened Reinforced Concrete Beam
Abstract
Starting with the premise that the choice of the optimal method for strengthening reinforced concrete (RC) structures is a complex task and that ferrocement strengthening is comparable to other advanced strengthening technologies due to its cost-effectiveness, ease of construction, and durability, this paper presents a comparative study of the flexural bearing capacity of RC beams strengthened with ferrocement strips applied by gluing. An overview of the life cycle assessment (LCA) based on embodied energy or CO2 is presented in the introduction, based on the existing literature review. The research includes tests of 15 RC beams of identical cross-sections (150/250 mm) and a span of 3000 mm. Strengthening was conducted by applying four types of ferrocement strips (different widths and wire mesh layers). Two factors were examined: the verification of the comprehensive FEM numerical model against the experimental results and the applicability of existing simplified calculation methods for sufficiently accurate results which could be used in regular practice. The results show that the failure forces obtained from numerical models and experimental models differ by no more than 3.94%. The increase in the bearing capacity of the strengthened models is up to 21.4%. The transformed area method for the cracked section showed good results when compared to the FEM and experimental models. The analytically calculated failure force is contingent upon the partial factor for variable action, which was explored within the 1.5–1.7 range.
Keywords