PLoS ONE (Jan 2017)

Interference figures of polarimetric interferometry analysis of the human corneal stroma.

  • Rodolfo Mastropasqua,
  • Mario Nubile,
  • Niccolò Salgari,
  • Manuela Lanzini,
  • Roberta Calienno,
  • Peter A Mattei,
  • Alessandra Sborgia,
  • Luca Agnifili

DOI
https://doi.org/10.1371/journal.pone.0178397
Journal volume & issue
Vol. 12, no. 6
p. e0178397

Abstract

Read online

A rotating polarimetric 90°-cross linear-filter interferometry system was used to detect the morphological characteristics and features of interference patterns produced in in-vivo corneal stroma in healthy human corneas of 23 subjects. The characteristic corneal isogyres presenting with an evident cross-shaped pattern, grossly aligned with the fixation axis, were observed in all patients with centers within the pupillary dark area, impeding the exact determination of the center point. During the rotational scan in 78.3% of the eyes the cross-shaped pattern of the isogyre gradually separated to form two distinct hyperbolic arcs in opposite quadrants, reaching their maximal separation at 45 degrees with respect to angle of cross-shaped pattern formation. The corneal cross and hyperbolic-pattern repeated every 90° throughout the 360° rotational scan. While the interpretation of the isogyres presents particular difficulties, two summary parameters can be extracted for each cornea: the presence/orientation of a single or two dark areas in post-processed images and isochromes. However, the development of dedicated software for semi-quantitative analysis of these parameters and enantiomorphism may become available in the near future. The possible application of polarimetric interferometry in the field of both corneal pathologies and corneal surgery may be of great interest for clinical purposes.