East European Journal of Physics (Jun 2022)

Comparison of Numerically Simulated and Measured Dose Rates for Gamma-Irradiation Facility

  • Volodymyr Morgunov,
  • Imre Madar,
  • Serhii Lytovchenko,
  • Volodymyr Chyshkala,
  • Bohdan Mazilin

DOI
https://doi.org/10.26565/2312-4334-2022-2-15
Journal volume & issue
no. 2

Abstract

Read online

The article provides a description of steps which were made to make comparison between numerically simulated and measured dose rates in Izotop gamma-irradiation facility (Budapest, Hungary) Numerical simulation was carried out with the help of software toolkit GEANT4. Dose measurement were made by ethanol-chlorobenzene (ECB) dosimeters. The comparison shows a good agreement between simulated and measured values. Worst accuracy was 17.08%.

Keywords