Energies (Jan 2021)

Interturn Short-Circuit Fault Detection of a Five-Phase Permanent Magnet Synchronous Motor

  • Zhongyi Yang,
  • Yiguang Chen

DOI
https://doi.org/10.3390/en14020434
Journal volume & issue
Vol. 14, no. 2
p. 434

Abstract

Read online

Interturn short circuits are a common fault of permanent magnet synchronous motors (PMSMs). This paper proposes a new method to detect the interturn short-circuit fault (ISCF) of a five-phase PMSM. The method first takes the command voltage and measured current of each phase winding as the original signal and then obtains the delay signal orthogonal to the original signal via Hilbert transform. Then, the generalized instantaneous reactive power of each phase can be calculated from the orthogonal voltage and current signals of each phase. Finally, the influence of the ISCF on the generalized instantaneous reactive power of each phase is analyzed under different working conditions. By comparing the difference in the generalized instantaneous reactive power of each phase, it can be determined which phase winding has the ISCF. The proposed method is verified by simulated and experimental results.

Keywords