Chemical Engineering Transactions (Sep 2014)

The Power of Online Proton Transfer Reaction - Mass Spectrometry (PTR-MS) Measurement of Odorous Emissions from a Pig House

  • K. Van Huffel,
  • M. Hansen,
  • A. Feilberg,
  • D. Liu,
  • H. Van Langenhove

DOI
https://doi.org/10.3303/CET1440041
Journal volume & issue
Vol. 40

Abstract

Read online

Online monitoring of odorous compounds in the ventilation air was applied in an experimental pig house in Denmark. The measurements were executed by proton-transfer-reaction – mass spectrometry (PTR-MS) while grab samples are used to confirm the identity of the compounds. Sorbent tubes samples were analysed by gas chromatography – mass spectrometry analysis (GC-MS) and Tedlar bags samples by gas chromatography – sulfur chemiluminescence detector (GC-SCD). For three target odorants, dimethyl sulfide, propanoic acid and p-cresol, the reproducibility after averaging over 1 hour was in the same order of magnitude for both grab and continuous sampling (