Journal of Clinical Medicine (Feb 2024)

Analysis of 1051 ICD Leads Extractions in Search of Factors Affecting Procedure Difficulty and Complications: Number of Coils, Tip Fixation and Position—Does It Matter?

  • Andrzej Kutarski,
  • Wojciech Jacheć,
  • Paweł Stefańczyk,
  • Wojciech Brzozowski,
  • Andrzej Głowniak,
  • Dorota Nowosielecka

DOI
https://doi.org/10.3390/jcm13051261
Journal volume & issue
Vol. 13, no. 5
p. 1261

Abstract

Read online

Background: Implantable cardioverter-defibrillator (ICD) leads are considered a risk factor for major complications (MC) during transvenous lead extraction (TLE). Methods: We analyzed 3878 TLE procedures (including 1051 ICD lead extractions). Results: In patients with ICD lead removal, implant duration was almost half as long (69.69 vs. 114.0 months; p p p p p = 0.011). Multivariable regression analysis showed that ICD lead implant duration ≥120 months (OR = 2.956; p p = 0.003) but not passive-fixation ICD leads (1.361; p = 0.149) or single coil ICD leads (OR = 1.540; p = 0.177) were predictors of higher procedure complexity, but had no influence on MC or clinical and procedural success. ICD lead implant duration was of crucial importance, similar to the number of leads. Lead dwell time >10 years is associated with a high level of procedure difficulty and complexity but not with MC and procedure-related deaths. Conclusions: The main factors affecting the transvenous removal of ICD leads are implant duration and the number of targeted ICD leads. Dual coil and passive fixation ICD leads are a bit more difficult to extract whereas fixation mechanism and tip position play a much less dominant role.

Keywords