The main factors of stress distribution in MCRs are the magnetostriction effect of the core materials and the magnetic force between gaps under DC bias excitation. This article developed a coupling model for MCRs considering Maxwell magnetic force and magnetostriction under DC flux density biases. The constitutive equations of the magnetic field and strain field are constructed based on the magnetic property curves with a new measured and analyzed method to consider DC magnetic flux biases, which is the key contributions of this study. Then, the electromagnetic vibration properties of the MCR model are calculated and analyzed. To prove the validity of the proposed method, the vibration of a 4.4 kVar-220 V MCR is tested and analyzed.