BMC Research Notes (Mar 2024)
Shower dehumidification to reduce nontuberculous mycobacteria aerosolization
Abstract
Abstract Objective Nontuberculous mycobacteria (NTM) are environmentally acquired opportunistic pathogens that can cause recalcitrant lung disease. Prior reports have demonstrated links between shower use and infections, yet the aerosolization of NTM from showerheads, as well as the humidity levels that may modulate NTM aerosolization from showerheads is less studied. The objective of the current study was to investigate the role of humidity in NTM aerosolization among showers in homes located in a geographic area with high lung disease incidence, Hawai’i, and test whether deployment of a dehumidifier in well-ventilated bathrooms reduce NTM exposure. Results Across two sampling events and five showers, existing NTM showerhead biofilms along with shower air were sampled at three points: pre-shower, post-shower, and post-dehumidification. In each of the sampling events, respiratory relevant NTM species were identified from shower biofilms, which were also detected in aerosolized shower air after showering events, but not after the shower was dehumidified and bathrooms vented. While sample size was small, these data suggest running a shower is a possible source of NTM aerosolization and using a commercial household dehumidifier in conjunction with opening bathroom doors and windows may be simple, cost-effective interventions to reduce environmental NTM exposures.