Mechanics and Advanced Technologies (Dec 2018)
The tibial fractures fixation system deformation characteristics
Abstract
The characteristics of stiffness are studied and the fixation means allowable load at fractures of the distal epimetazh of the tibia is calculated. The processes of a fracture points mutual displacements development under the influence of long-term cyclic loads are studied. Metal osteosynthesis was performed using various types of medial and lateral plates with angular stability and blocked plates for fixing fractures in the distal epimetazh of the tibia. The tests are conducted under the influence of actual physiological loads of compression, bending and torsion, including cyclic loading modes. Keywords: osteosynthesis; tibial, occipital plates, stiffness of fracture fixation, fracture fixation strength, fracture fixation stability
Keywords