Apical debris extrusion during instrumentation of oval root canals in primary teeth using manual versus motorized files: an ex vivo study
Abstract
Abstract This study aimed to assess the apical extrusion of debris during instrumentation of primary canines using three endodontic file types. Forty-five extracted primary canines were randomly assigned to three instrumentation groups (n = 15): Hand K-files; and the motorized Kedo-S files and XP-endo Shaper files. The apically extruded debris produced during the procedure was collected and dried in pre-weighed Eppendorf tubes, and the mass of debris was calculated. The time required for the endodontic procedure was also recorded. Analysis of variance (ANOVA) and Tukey’s post hoc test were used with a significance level set at 5%. XP-endo Shaper and Kedo-S files extruded significantly less debris compared with hand K-files with means of 0.84 ± 0.31 and 1.20 ± 0.67 mg respectively, compared to 2.13 ± 0.31 mg (p < 0.0001). No significant difference was found between the two motorized files. Less time was required to complete the procedure with the XP-endo Shaper compared to the hand K-files (p < 0.0001) and Kedo-S files (p < 0.0001). Within the limitations of the present study, it may be concluded that motorized files extruded less debris and required less instrumentation time compared to traditional K-files, which could benefit paediatric patients with root canal treatment needs.