Case Reports in Gastroenterology (Jun 2018)

Acute Small Bowel Perforation Caused by Obstruction of a Novel Tag-Less AgileTM Patency Capsule

  • Katsuji Sawai,
  • Takanori Goi,
  • Yumi  Takegawa,
  • Yoshihiko Ozaki,
  • Seiichi  Taguchi,
  • Hidetaka Kurebayashi,
  • Hiroyuki Suto

DOI
https://doi.org/10.1159/000490097
Journal volume & issue
Vol. 12, no. 2
pp. 337 – 343

Abstract

Read online

A 74-year-old man visited our hospital complaining of abdominal pain. An abdominal computed tomography scan showed multiple wall thickness of the small bowel. Capsule endoscopy was recommended for further evaluation, and patency capsule examination was performed. Eighteen hours after patency capsule ingestion, he experienced small bowel perforation with severe peritonitis caused by intestinal pressure rising because of the patency capsule trapped in his terminal ileum. An ileocolic resection was performed, including the removal of the sclerotic ileum as an emergency surgery. A pathological examination showed transmural inflammation and multiple ulcers with perforation of the small intestine, consistent with Crohn’s disease. Here, we report a rare and valuable case of novel tag-less AgileTM patency capsule (Given Imaging Ltd., Yoqneam, Israel) retention leading to small bowel perforation.

Keywords