Bio-Protocol (Mar 2018)

Alphavirus Purification Using Low-speed Spin Centrifugation

  • Vamseedhar Rayaprolu,
  • Jolene Ramsey,
  • Joseph Wang,
  • Suchetana Mukhopadhyay

DOI
https://doi.org/10.21769/BioProtoc.2772
Journal volume & issue
Vol. 8, no. 6

Abstract

Read online

Chemical and sedimentation procedures are used to purify virus particles. While these approaches are successful for wild-type viruses, they are often not feasible for purifying mutant viruses with assembly defects. We combined two published methods (Atasheva et al., 2013; Moller-Tank et al., 2013), to generate a protocol that uses low-speed centrifugation to purify both wildtype and mutant enveloped virus particles at high yield with minimal handling steps. This protocol has successfully been used to purify alphavirus particles for imaging and structural studies (Wang et al., 2015; Ramsey et al., 2017).