Clinical and Translational Radiation Oncology (Dec 2017)

VMAT radiation-induced nausea and vomiting in adjuvant breast cancer radiotherapy: The incidental effect of low-dose bath exposure

  • G. Lazzari,
  • A. Terlizzi,
  • M.G. Leo,
  • G. Silvano

Journal volume & issue
Vol. 7
pp. 43 – 48

Abstract

Read online

Background and purpose: To investigate the hypothesis on low-dose bath exposure related to radiation-induced nausea and vomiting (RINV) in adjuvant breast volumetric modulated arch therapy (VMAT). Methods and materials: A total of 106 consecutive breast cancer patients (pts) treated with adjuvant radiotherapy (RT) with VMAT from January 2013 to May 2016 were evaluated retrospectively. For each pt, a planning CT was reimported and the coeliac plexus and gastroesophageal junction with gastric mouth (GEJCPs) were contoured as a new organ at risk (OAR) in the upper abdominal area. RINV was associated with Dmax and Dmean to GEJCPs. Univariate analysis with χ2, t-test, and Pearson’s covariance was used for statistical analysis. Results: Of 106 pts, 64% complained of acute RINV according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4.03. RINV was related to Dmax > 10 Gy and Dmean > 3 Gy to GEJCPs (P < 0.005). The radiation breast side and planning target volume (PTV) correlated with RINV. Conclusions: RINV in VMAT breast radiotherapy could be a new emerging acute side effect due to a low dose bath to upper abdominal structures such as the GEJCPs. A Dmax < 10 Gy and Dmean < 3 Gy to GEJCPs should be constrained in VMAT planning to minimize RINV risk in breast radiotherapy. Keywords: Volumetric modulated arch therapy, Gastroesophageal junction, Coeliac plexus, Nausea, Vomit